| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue was discovered in SMA Solar Technology products. The inverters make use of a weak hashing algorithm to encrypt the password for REGISTER requests. This hashing algorithm can be cracked relatively easily. An attacker will likely be able to crack the password using offline crackers. This cracked password can then be used to register at the SMA servers. NOTE: the vendor's position is that "we consider the probability of the success of such manipulation to be extremely low." Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected |
| An issue was discovered on Mimosa Client Radios before 2.2.3. In the device's web interface, there is a page that allows an attacker to use an unsanitized GET parameter to download files from the device as the root user. The attacker can download any file from the device's filesystem. This can be used to view unsalted, MD5-hashed administrator passwords, which can then be cracked, giving the attacker full admin access to the device's web interface. This vulnerability can also be used to view the plaintext pre-shared key (PSK) for encrypted wireless connections, or to view the device's serial number (which allows an attacker to factory reset the device). |
| The default SSH configuration in Rapid7 Nexpose hardware appliances shipped before June 2017 does not specify desired algorithms for key exchange and other important functions. As a result, it falls back to allowing ALL algorithms supported by the relevant version of OpenSSH and makes the installations vulnerable to a range of MITM, downgrade, and decryption attacks. |
| An issue was discovered in Valve Steam Link build 643. Root passwords longer than 8 characters are truncated because of the default use of DES (aka the CONFIG_FEATURE_DEFAULT_PASSWD_ALGO="des" setting). |
| The airbag detonation algorithm allows injury to passenger-car occupants via predictable Security Access (SA) data to the internal CAN bus (or the OBD connector). This affects the airbag control units (aka pyrotechnical control units or PCUs) of unspecified passenger vehicles manufactured in 2014 or later, when the ignition is on and the speed is less than 6 km/h. Specifically, there are only 256 possible key pairs, and authentication attempts have no rate limit. In addition, at least one manufacturer's interpretation of the ISO 26021 standard is that it must be possible to calculate the key directly (i.e., the other 255 key pairs must not be used). Exploitation would typically involve an attacker who has already gained access to the CAN bus, and sends a crafted Unified Diagnostic Service (UDS) message to detonate the pyrotechnical charges, resulting in the same passenger-injury risks as in any airbag deployment. |
| An issue was discovered in heinekingmedia StashCat through 1.7.5 for Android, through 0.0.80w for Web, and through 0.0.86 for Desktop. To encrypt messages, AES in CBC mode is used with a pseudo-random secret. This secret and the IV are generated with math.random() in previous versions and with CryptoJS.lib.WordArray.random() in newer versions, which uses math.random() internally. This is not cryptographically strong. |
| mod_ns in Red Hat Enterprise Linux Desktop 7, Red Hat Enterprise Linux HPC Node 7, Red Hat Enterprise Linux Server 7, and Red Hat Enterprise Linux Workstation 7 allows remote attackers to force the use of ciphers that were not intended to be enabled. |
| The image signature algorithm in OpenStack Glance 11.0.0 allows remote attackers to bypass the signature verification process via a crafted image, which triggers an MD5 collision. |
| Apache WSS4J before 1.6.17 and 2.0.x before 2.0.2 improperly leaks information about decryption failures when decrypting an encrypted key or message data, which makes it easier for remote attackers to recover the plaintext form of a symmetric key via a series of crafted messages. NOTE: this vulnerability exists because of an incomplete fix for CVE-2011-2487. |
| Apache Hadoop before 0.23.4, 1.x before 1.0.4, and 2.x before 2.0.2 generate token passwords using a 20-bit secret when Kerberos security features are enabled, which makes it easier for context-dependent attackers to crack secret keys via a brute-force attack. |
| Novell iManager 2.7 before SP7 Patch 9, NetIQ iManager 3.x before 3.0.2.1, Novell eDirectory 8.8.x before 8.8 SP8 Patch 9 Hotfix 2, and NetIQ eDirectory 9.x before 9.0.2 Hotfix 2 (9.0.2.2) use the deprecated MD5 hashing algorithm in a communications certificate. |
| Sympa before 6.2.62 relies on a cookie parameter for certain security objectives, but does not ensure that this parameter exists and has an unpredictable value. Specifically, the cookie parameter is both a salt for stored passwords and an XSS protection mechanism. |
| Fresenius Kabi Vigilant Software Suite (Mastermed Dashboard) version 2.0.1.3 issues authentication tokens to authenticated users that are signed with a symmetric encryption key. An attacker in possession of the key can issue valid JWTs and impersonate arbitrary users. |
| The use of a broken or risky cryptographic algorithm in Philips Vue PACS versions 12.2.x.x and prior is an unnecessary risk that may result in the exposure of sensitive information. |
| The SSL/TLS configuration of Fresenius Kabi Agilia Link + version 3.0 has serious deficiencies that may allow an attacker to compromise SSL/TLS sessions in different ways. An attacker may be able to eavesdrop on transferred data, manipulate data allegedly secured by SSL/TLS, and impersonate an entity to gain access to sensitive information. |
| Fresenius Kabi Agilia Link + version 3.0 does not enforce transport layer encryption. Therefore, transmitted data may be sent in cleartext. Transport layer encryption is offered on Port TCP/443, but the affected service does not perform an automated redirect from the unencrypted service on Port TCP/80 to the encrypted service. |
| MMP: All versions prior to v1.0.3, PTP C-series: Device versions prior to v2.8.6.1, and PTMP C-series and A5x: Device versions prior to v2.5.4.1 uses the MD5 algorithm to hash the passwords before storing them but does not salt the hash. As a result, attackers may be able to crack the hashed passwords. |
|
IBM Spectrum Control 5.4 uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive information. IBM X-Force ID: 233982.
|
|
IBM Security Verify Governance, Identity Manager 10.0.1 uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive information. IBM X-Force ID: 225007.
|
| Versions `<=8.5.1` of `jsonwebtoken` library could be misconfigured so that legacy, insecure key types are used for signature verification. For example, DSA keys could be used with the RS256 algorithm. You are affected if you are using an algorithm and a key type other than a combination listed in the GitHub Security Advisory as unaffected. This issue has been fixed, please update to version 9.0.0. This version validates for asymmetric key type and algorithm combinations. Please refer to the above mentioned algorithm / key type combinations for the valid secure configuration. After updating to version 9.0.0, if you still intend to continue with signing or verifying tokens using invalid key type/algorithm value combinations, you’ll need to set the `allowInvalidAsymmetricKeyTypes` option to `true` in the `sign()` and/or `verify()` functions. |