| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Use of hard-coded, the same among all vulnerable installations SQLite credentials vulnerability in SIGNUM-NET FARA allows to read and manipulate local-stored database.This issue affects FARA: through 5.0.80.34. |
| In Optigo Networks ONS NC600 versions 4.2.1-084 through 4.7.2-330, an attacker could connect with the device's ssh server and utilize the system's components to perform OS command executions. |
| A vulnerability was discovered in the storage policy for certain sets of encryption keys in the HPE Telco Network Function Virtual Orchestrator. Successful Exploitation could lead to unauthorized parties gaining access to sensitive system information. |
| A vulnerability was discovered in the storage policy for certain sets of authentication keys in the HPE Telco Network Function Virtual Orchestrator. Successful Exploitation could lead to unauthorized parties gaining access to sensitive system information. |
| Hard-coded login credentials were found in HPE Networking Instant On Access Points, allowing anyone with knowledge of it to bypass normal device authentication. Successful exploitation could allow a remote attacker to gain administrative access to the system. |
| Vulnerabilities* in ActADUR local server product, developed and maintained by ProTNS, allows Remote Code Inclusion on host systems.
* vulnerabilities:
*
Improper Neutralization of Special Elements used in a Command ('Command Injection')
* Use of Hard-coded Credentials
* Improper Authentication
* Binding to an Unrestricted IP Address
The vulnerability has been rated as critical.This issue affects ActADUR: from v2.0.1.9 before v2.0.2.0., hence updating to version v2.0.2.0. or above is required. |
| We observed that Intellispace Portal binaries doesn’t have any protection mechanisms to prevent reverse engineering. Specifically, the app’s code is not obfuscated, and no measures are in place to protect against decompilation, disassembly, or debugging. As a result, attackers can reverse-engineer the application to gain insights into its internal workings, which can potentially lead to the discovery of sensitive information, business logic flaws, and other vulnerabilities.
Utilizing this flaw, the attacker was able to identify the Hardcoded credentials from PortalUsersDatabase.dll, which contains .NET remoting definition. Inside the namespace PortalUsersDatabase, the class Users contains the functions CreateAdmin and CreateService that are used to initialize accounts in the Portal service. Both CreateAdmin and CreateService functions contain a hardcoded encrypted password along with its respective salt that are set with the function SetInitialPasswordAndSalt.
This issue affects IntelliSpace Portal: 12 and prior; Advanced Visualization Workspace: 15. |
| A predefined administrative account is not documented and cannot
be deactivated. This account cannot be misused from the network, only by local
users on the server. |
| Use of Hard-coded Credentials vulnerability in GE Vernova EnerVista UR Setup allows Privilege Escalation. The local user database is encrypted using an hardcoded password retrievable by an attacker analyzing the application code. |
| CWE-798: Use of Hard-coded Credentials |
| A vulnerability has been found in Tenda i24, 4G03 Pro, 4G05, 4G08, G0-8G-PoE, Nova MW5G and TEG5328F up to 65.10.15.6. Affected is an unknown function of the component Shadow File. Such manipulation with the input Fireitup leads to hard-coded credentials. An attack has to be approached locally. The exploit has been disclosed to the public and may be used. |
| A vulnerability has been found in TOZED ZLT M30S and ZLT M30S PRO 1.47/3.09.06. Affected is an unknown function of the component Web Interface. Such manipulation leads to hard-coded credentials. The attack needs to be initiated within the local network. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| IBM Sterling Connect:Direct for UNIX Container 6.3.0.0 through 6.3.0.6 Interim Fix 016, and 6.4.0.0 through 6.4.0.3 Interim Fix 019 IBM® Sterling Connect:Direct for UNIX contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. |
| A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system.
Other related CVE's are CVE-2025-14095 & CVE-2025-14097.
Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.
Required Configuration for Exposure:
Attacker requires physical access to the analyzer.
Temporary work Around:
Only authorized people can physically access the analyzer.
Permanent solution:
Local Radiometer representatives will contact all affected customers to discuss a permanent solution.
Exploit Status:
Researchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication. |
| The WorkExaminer Professional server installation comes with an FTP server that is used to receive the client logs on TCP port 12304. An attacker with network access to this port can use weak hardcoded credentials to login to the FTP server and modify or read data, log files and gain remote code execution as NT Authority\SYSTEM on the server by exchanging accessible service binaries in the WorkExaminer installation directory (e.g. "C:\Program File (x86)\Work Examiner Professional Server"). |
| Use of Hard-coded Credentials vulnerability in GoodWe Technologies Co., Ltd. GW1500‑XS allows anyone in physical proximity to the device to fully access the web interface of the inverter via Wi‑Fi.This issue affects GW1500‑XS: 1.1.2.1. |
| Certain models of D-Link wireless routers contain an undisclosed factory testing backdoor. Unauthenticated attackers on the local area network can force the device to enable Telnet service by accessing a specific URL and can log in by using the administrator credentials obtained from analyzing the firmware. |
| The WP2Speed Faster – Optimize PageSpeed Insights Score 90-100 plugin for WordPress is vulnerable to unauthorized access in all versions up to, and including, 1.0.1. This is due to the use of hardcoded credentials to authenticate all the incoming API requests. This makes it possible for unauthenticated attackers to overwrite CSS, update the trial settings, purge the cache, and find attachments. |
| In Eaton X303 3.5.16 - X303 3.5.17 Build 712, an attacker with network access to a XC-303 PLC can login as root over SSH. The root password is hardcoded in the firmware. NOTE: This vulnerability appears in versions that are no longer supported by Eaton. |
| IXON B.V. IXrouter IX2400 (Industrial Edge Gateway) v3.0 was discovered to contain hardcoded root credentials stored in the non-volatile flash memory. This vulnerability allows physically proximate attackers to gain root access via UART or SSH. |