Export limit exceeded: 405420 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (405420 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-63351 2026-10-13 6.1 Medium
Affected devices do not properly validate and sanitize visual properties of calculated signals contained in imported CSV trace files before rendering them on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Successful exploitation could allow attacker-controlled JavaScript to execute in the user’s browser session and perform PLC operations through the web server within the scope of the user’s authorization.
CVE-2026-63353 2026-10-13 9.6 Critical
Affected devices do not properly sanitize comment fields contained in imported trace files before rendering them on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Successful exploitation could allow attacker-controlled JavaScript to execute in the user’s browser session and perform PLC operations through the web server within the scope of the user’s authorization.
CVE-2026-63354 2026-10-13 9.6 Critical
Affected devices do not properly validate and sanitize visual marker data contained in imported CSV trace files before rendering it on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Successful exploitation could allow attacker-controlled JavaScript to execute in the user’s browser session and perform PLC operations through the web server within the scope of the user’s authorization.
CVE-2026-102076 2026-10-13 7.5 High
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.7), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.21), APOGEE PXC Modular (BACnet) (All versions < V3.5.7), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.21), TALON TC Compact (BACnet) (All versions < V3.5.7), TALON TC Modular (BACnet) (All versions < V3.5.7). The affected product web service does not properly validate user-supplied input in upload code. This could allow an unauthenticated remote attacker to cause a denial of service.
CVE-2026-109156 1 Seldonio 1 Mlserver 2026-10-13 6.3 Medium
A vulnerability has been found in SeldonIO MLServer up to 1.6.1. Affected is the function _extract_env of the file mlserver/env.py of the component environment_tarball Handler. Such manipulation leads to path traversal. The attack may be performed from remote. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-109155 1 Deeppavlov 1 Deeppavlov 2026-10-13 6.3 Medium
A flaw has been found in DeepPavlov up to 1.7.0. This impacts the function untar of the component Model Download Handler. This manipulation causes path traversal. The attack is possible to be carried out remotely. The project was informed of the problem early through an issue report but has not responded yet.
CVE-2026-109153 1 Mosaicml 1 Composer 2026-10-13 6.3 Medium
A vulnerability was detected in MosaicML Composer up to 0.32.1. This affects the function tarball.extractall of the file composer/utils/checkpoint.py of the component Checkpoint Extraction. The manipulation results in path traversal. The attack can be executed remotely. The vendor was contacted early about this disclosure.
CVE-2026-109149 1 Beautifier 1 Js-beautify 2026-10-13 5.3 Medium
A weakness has been identified in beautifier js-beautify up to 1.15.1/2.0.3. The affected element is an unknown function. Executing a manipulation can lead to uncontrolled memory allocation. The attack may be launched remotely. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-109162 1 Typo3 1 Typo3 Cms 2026-10-13 N/A
Forms using FileUpload or ImageUpload elements with a custom saveToFileMount configured stored uploaded files in the default storage folder 1:/user_upload/ instead of the configured destination. This could cause uploaded files to end up in a publicly accessible storage even though a restricted, non-public storage had been configured. Files stored this way are served directly, without the access checks applied to non-public storages. Forms that use the default value for saveToFileMount are not affected. This issue affects TYPO3 CMS versions 14.0.0-14.3.8.
CVE-2026-85115 2026-10-13 5.5 Medium
A vulnerability has been identified in .NET Client Library for SIMATIC S7 Webserver API (All versions < V3.3.62). Affected applications do not properly redact PLC restore passwords from HTTP error exception messages. This could allow an attacker with access to logs or other diagnostic output to obtain the plaintext restore password and potentially perform unauthorized operations on the PLC.
CVE-2026-63357 2026-10-13 6.1 Medium
Affected devices do not properly sanitize calculated signal data contained in imported calculated signal files before rendering it on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted file. Successful exploitation could allow attacker-controlled JavaScript to execute in the user’s browser session and perform PLC operations through the web server within the scope of the user’s authorization.
CVE-2026-63352 2026-10-13 6.1 Medium
Affected devices do not properly sanitize calculated signal data contained in imported CSV trace files before rendering it on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Successful exploitation could allow attacker-controlled JavaScript to execute in the user’s browser session and perform PLC operations through the web server within the scope of the user’s authorization.
CVE-2026-44414 2026-10-13 6.8 Medium
A vulnerability has been identified in Industrial Edge Cloud Device (IECD), Industrial Edge Device Kit - arm64 V1.10, Industrial Edge Device Kit - arm64 V1.11, Industrial Edge Device Kit - arm64 V1.12, Industrial Edge Device Kit - arm64 V1.13, Industrial Edge Device Kit - arm64 V1.14, Industrial Edge Device Kit - arm64 V1.15, Industrial Edge Device Kit - arm64 V1.16, Industrial Edge Device Kit - arm64 V1.17, Industrial Edge Device Kit - arm64 V1.18, Industrial Edge Device Kit - arm64 V1.19, Industrial Edge Device Kit - arm64 V1.20, Industrial Edge Device Kit - arm64 V1.21, Industrial Edge Device Kit - arm64 V1.22, Industrial Edge Device Kit - arm64 V1.23, Industrial Edge Device Kit - arm64 V1.24, Industrial Edge Device Kit - arm64 V1.25, Industrial Edge Device Kit - arm64 V1.26, Industrial Edge Device Kit - arm64 V1.27, Industrial Edge Device Kit - arm64 V1.28, Industrial Edge Device Kit - arm64 V1.5, Industrial Edge Device Kit - arm64 V1.6, Industrial Edge Device Kit - arm64 V1.7, Industrial Edge Device Kit - arm64 V1.8, Industrial Edge Device Kit - arm64 V1.9, Industrial Edge Device Kit - x86-64 V1.10, Industrial Edge Device Kit - x86-64 V1.11, Industrial Edge Device Kit - x86-64 V1.12, Industrial Edge Device Kit - x86-64 V1.13, Industrial Edge Device Kit - x86-64 V1.14, Industrial Edge Device Kit - x86-64 V1.15, Industrial Edge Device Kit - x86-64 V1.16, Industrial Edge Device Kit - x86-64 V1.17, Industrial Edge Device Kit - x86-64 V1.18, Industrial Edge Device Kit - x86-64 V1.19, Industrial Edge Device Kit - x86-64 V1.20, Industrial Edge Device Kit - x86-64 V1.21, Industrial Edge Device Kit - x86-64 V1.22, Industrial Edge Device Kit - x86-64 V1.23, Industrial Edge Device Kit - x86-64 V1.24, Industrial Edge Device Kit - x86-64 V1.25, Industrial Edge Device Kit - x86-64 V1.26, Industrial Edge Device Kit - x86-64 V1.27, Industrial Edge Device Kit - x86-64 V1.28, Industrial Edge Device Kit - x86-64 V1.5, Industrial Edge Device Kit - x86-64 V1.6, Industrial Edge Device Kit - x86-64 V1.7, Industrial Edge Device Kit - x86-64 V1.8, Industrial Edge Device Kit - x86-64 V1.9, Industrial Edge Own Device (IEOD), Industrial Edge Virtual Device (IEVD), SCALANCE LPE9413 (6GK5998-3GS01-2AC2), SCALANCE LPE9433 (6GK5998-3GS11-2AC2), SIMATIC IoT2050 Advanced IED (6ES7647-0BW00-1YA2), SIMATIC IoT2050 SM IED (6ES7647-0CW00-1AA2), SIMATIC IPC BX-21A Industrial Edge Device, SIMATIC IPC BX-39A Industrial Edge Device, SIMATIC IPC BX-59A Industrial Edge Device, SIMATIC IPC127E Industrial Edge Device, SIMATIC IPC227E Industrial Edge Device, SIMATIC IPC227G Industrial Edge Device, SIMATIC IPC427E Industrial Edge Device, SIMATIC IPC847E Industrial Edge Device. Affected systems do not properly restrict access to internal APIs and paths for authenticated users. This could allow an authenticated remote attacker to access sensitive internal information, which in the worst case could be leveraged to facilitate unauthorized access to the system.
CVE-2026-41125 1 Siemens 29 Blueplanet 100 Nx3 M8, Blueplanet 100 Tl3 Gen2, Blueplanet 105 Tl3 and 26 more 2026-10-13 6 Medium
A vulnerability has been identified in blueplanet 100 NX3 M8 (All versions), blueplanet 100 TL3 GEN2 (All versions), blueplanet 105 TL3 (All versions < V3.92), blueplanet 105 TL3 GEN2 (All versions), blueplanet 110 TL3 (All versions < V3.92), blueplanet 125 NX3 M10 (All versions), blueplanet 125 TL3 (All versions < V3.92), blueplanet 125 TL3 GEN2 (All versions), blueplanet 137 TL3 (All versions < V3.92), blueplanet 150 TL3 (All versions < V3.92), blueplanet 150 TL3 GEN2 (All versions), blueplanet 155 TL3 (All versions < V3.92), blueplanet 155 TL3 GEN2 (All versions), blueplanet 165 TL3 (All versions < V3.92), blueplanet 165 TL3 GEN2 (All versions), blueplanet 87.0 TL3 (All versions < V3.92), blueplanet 87.0 TL3 GEN2 (All versions), blueplanet 92.0 TL3 (All versions < V3.92), blueplanet 92.0 TL3 GEN2 (All versions), blueplanet gridsave 110 TL3-S (All versions < V3.92), blueplanet gridsave 137 TL3-S (All versions < V3.92), blueplanet gridsave 92.0 TL3-S (All versions < V3.92). Improper neutralization of special elements used in an sql command ('sql injection') in KACO Meteor server allows an authorized attacker to elevate privileges over a local network.
CVE-2025-40817 1 Siemens 2 Logo!, Siplus Logo! 2026-10-13 6.5 Medium
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to change time of the device, which means the device could behave differently.
CVE-2025-40816 1 Siemens 2 Logo!, Siplus Logo! 2026-10-13 7.6 High
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable.
CVE-2025-40815 1 Siemens 2 Logo!, Siplus Logo! 2026-10-13 7.2 High
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code.
CVE-2025-40759 2026-10-13 7.8 High
A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2). Affected products do not properly sanitize stored security properties when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
CVE-2024-54678 1 Siemens 13 Simatic Pcs Neo, Simatic S7-plcsim, Simatic Step 7 and 10 more 2026-10-13 8.2 High
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2), TIA Portal Test Suite V20 (All versions < V20 Update 4). Affected products do not properly sanitize Interprocess Communication input received through a Windows Named Pipe accessible to all local users. This could allow an authenticated local attacker to cause a type confusion and execute arbitrary code within the affected application.
CVE-2024-52051 2026-10-13 7.3 High
A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC S7-PLCSIM V18 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 6), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC Unified PC Runtime V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions < V18 Update 6), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1). The affected devices do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to locally execute arbitrary commands in the host operating system with the privileges of the user.